High Strenghth High Modulus High Corrosion Resistance GFRP Rebar for Metro Correspond to CJJ-T192-2012 and JGT 406-2013

We specialize in the production of GFRP for metro and obtain the unanimously approved of client. And the GFRP for meto meet the international safety standard of CJJ-T192-2012 and JGT 406-2013. The product can be used for replacing the steel rebar as it get the advantage as composite material and...

Send InquiryChat Now

Product Details

We specialize in the production of GFRP for metro and obtain the unanimously approved of client. And the GFRP for meto meet the international safety standard of CJJ-T192-2012 and JGT 406-2013. The product can be used for replacing the steel rebar as it get the advantage as composite material and gain the good appraisement by the customer.

(1)High Corrosion Resistance:The base materials which is used by the bolt are durable materials, also they are molded through the composite process. The service life  is over 100 years. They can be thought as permanent support materials;

(2)Cuttability: It avoids damages to cutter heads, and does not delay excavation;

(3)Anti-static:It has no electrical conductivity, and no sparks will be produced when being cut. It is particularly suitable for high gas zones;

(4)Low Weight:The weight is only 1/4 that of a steel bar with the same diameter. Therefore, the labor intensity is greatly reduced, and the transportation cost is reduced at the same time;

(5)Non-flammable: It is non-flammable and has high thermal isolation;

(6)High Tensile Strength:The load is approximately double that of a steel bar with the same diameter

Type No.

Diameter (mm)

Ultimate tensile strength (MPa)

Modulus of elasticity    (GPa)

Ultimate shear strength (MPa)

B70-12

12

600-900

>40

110-150

B70-16

16

550-850

B70-25

25

500-800

B70-32

36

500-700

B70-40

40

450-600


(1)Classification

NO.

Standard number

Standard name

1

GB 50608-2010

Technical code for infrastructure application of FRP composites

2

JG/T406-2013

Glass fibre reinforced plastics rebar for civil engineering

3

ISO 10406-1-2013

Fibre-reinforced polymer (FRP) reinforcement of concrete. Test methods. Part 1:FRP bars and grids

4

ACI 440.3R-04

Guide Test Methods for Fiber-ReinforcedPolymers (FRPs) for Reinforcing orStrengthening Concrete Structures

5

CSA-S806-02 -2002

Design and Construction of Building Components with Fibre Reinforced Polymers

Inquiry